Welcome to the Library Catalog of "Dunarea de Jos" University of Galati

Seismic Performance of Corroded Reinforced Concrete Structures Retrofitted with FRP [electronic resource] / by Dejian Shen.

By: Contributor(s): Material type: TextPublisher: Singapore : Springer Nature Singapore : Imprint: Springer, 2024Edition: 1st ed. 2024Description: XV, 381 p. 244 illus., 84 illus. in color. online resourceContent type:
  • text
Media type:
  • computer
Carrier type:
  • online resource
ISBN:
  • 9789819979844
Subject(s):
Additional physical formats: Printed edition:: No title; Printed edition:: No title; Printed edition:: No titleLOC classification:
  • TA1-2040
Online resources:
Contents:
Introduction -- Bond stress-slip relationship between BFRP sheets and concrete under dynamic loading -- Retrofitting of reinforced concrete beam with BFRP sheets -- Retrofitting of corrosion-damaged reinforced concrete columns with BFRPs -- Retrofitting of corrosion-damaged reinforced concrete beam-column joints with BFRP sheets -- Retrofitting of corrosion-damaged reinforced concrete shear walls with BFRP sheets -- Bond behavior between BFRP bars and concrete under static and dynamic loading.
In: Springer Nature eBookSummary: This monograph is written based on the author's research on seismic assessment and retrofitting of corrosion-damaged reinforced concrete structures during the recent two decades. It points out that reinforcement corrosion is one of the main reasons that contribute to the deterioration of the seismic performances and durability of reinforced concrete structures. It illustrates that the mechanism of reinforcement corrosion should be investigated to propose a method for evaluating the seismic performance of corroded components and structures. It calls for a comprehensive investigation on the bond performance between corroded reinforcing bars and concrete, as well as the degradation law of seismic performance of corroded beams, columns, beam column joints, and shear walls from the perspectives of materials, components, and structures. With the promotion and application of composite materials, fiber reinforced polymer (FRP) has been proposed as an ideal material for retrofitting reinforced concrete structures. By emphasizing the mechanism of reinforcement corrosion and the integrated evaluation of materials, components, and structures, this monograph offers an idea of using FRP to retrofit the seismic performance of corroded reinforced concrete structures. It is designed as a reference work for professionals or practitioners and a textbook for undergraduates or postgraduates. This book provides valuable knowledge and useful methods that can be considered in the field of seismic assessment and retrofitting of corrosion-damaged reinforced concrete structures with other FRPs.
Item type: List(s) this item appears in: Titluri cărți electronice Springer Nature 2025 (10631 titluri)
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
No physical items for this record

Introduction -- Bond stress-slip relationship between BFRP sheets and concrete under dynamic loading -- Retrofitting of reinforced concrete beam with BFRP sheets -- Retrofitting of corrosion-damaged reinforced concrete columns with BFRPs -- Retrofitting of corrosion-damaged reinforced concrete beam-column joints with BFRP sheets -- Retrofitting of corrosion-damaged reinforced concrete shear walls with BFRP sheets -- Bond behavior between BFRP bars and concrete under static and dynamic loading.

This monograph is written based on the author's research on seismic assessment and retrofitting of corrosion-damaged reinforced concrete structures during the recent two decades. It points out that reinforcement corrosion is one of the main reasons that contribute to the deterioration of the seismic performances and durability of reinforced concrete structures. It illustrates that the mechanism of reinforcement corrosion should be investigated to propose a method for evaluating the seismic performance of corroded components and structures. It calls for a comprehensive investigation on the bond performance between corroded reinforcing bars and concrete, as well as the degradation law of seismic performance of corroded beams, columns, beam column joints, and shear walls from the perspectives of materials, components, and structures. With the promotion and application of composite materials, fiber reinforced polymer (FRP) has been proposed as an ideal material for retrofitting reinforced concrete structures. By emphasizing the mechanism of reinforcement corrosion and the integrated evaluation of materials, components, and structures, this monograph offers an idea of using FRP to retrofit the seismic performance of corroded reinforced concrete structures. It is designed as a reference work for professionals or practitioners and a textbook for undergraduates or postgraduates. This book provides valuable knowledge and useful methods that can be considered in the field of seismic assessment and retrofitting of corrosion-damaged reinforced concrete structures with other FRPs.

There are no comments on this title.

to post a comment.
Biblioteca Universității "Dunărea de Jos" din Galați