| 000 | 04053nam a22006015i 4500 | ||
|---|---|---|---|
| 001 | 978-981-96-0975-8 | ||
| 003 | DE-He213 | ||
| 005 | 20251030114931.0 | ||
| 007 | cr nn 008mamaa | ||
| 008 | 250124s2024 si | s |||| 0|eng d | ||
| 020 |
_a9789819609758 _9978-981-96-0975-8 |
||
| 024 | 7 |
_a10.1007/978-981-96-0975-8 _2doi |
|
| 050 | 4 | _aR895-920 | |
| 072 | 7 |
_aPHVD _2bicssc |
|
| 072 | 7 |
_aSCI003000 _2bisacsh |
|
| 072 | 7 |
_aPHVD _2thema |
|
| 100 | 1 |
_aManap, Muhammad Faris bin Abd. _eauthor. _4aut _4http://id.loc.gov/vocabulary/relators/aut _990430 |
|
| 245 | 1 | 0 |
_aTotal Hip Replacement (THR) _h[electronic resource] : _bEffect of Inclination and Anteversion Angle on the Performance of Epoxy-UHMWPE Acetabular Cup / _cby Muhammad Faris bin Abd Manap, Solehuddin Shuib, Ahmad Zafir Romli. |
| 250 | _a1st ed. 2024. | ||
| 264 | 1 |
_aSingapore : _bSpringer Nature Singapore : _bImprint: Springer, _c2024. |
|
| 300 |
_aXVII, 94 p. 52 illus., 39 illus. in color. _bonline resource. |
||
| 336 |
_atext _btxt _2rdacontent |
||
| 337 |
_acomputer _bc _2rdamedia |
||
| 338 |
_aonline resource _bcr _2rdacarrier |
||
| 347 |
_atext file _bPDF _2rda |
||
| 490 | 1 |
_aSpringerBriefs in Applied Sciences and Technology, _x2191-5318 |
|
| 505 | 0 | _aChapter 1. THE EFFECT OF INCLINATION AND ANTEVERSION ANGLE ON THE PERFORMANCE OF EPOXY-UHMWPE ACETABULAR CUP -- Chapter 2. METAL-ON-METAL TOTAL HIP REPLACEMENT AND SAFE ZONE ORIENTATION OF ACETABULAR CUP -- Chapter 3. FINITE ELEMENT ANALYSIS (FEA) OF METAL-ON-POLYMER (MoP) AND ACETABULAR CUP MATERIAL -- Chapter 4. NUMERICAL AND MATHEMATICAL MODELLING FOR ACETABULAR CUP ORIENTATION -- Chapter 5. EXPERIMENTAL WORK OF EPOXY-UHMWPE MATERIALS -- Chapter 6. ANALYTICAL RESULTS OF SAFE ZONE ORIENTATION -- Chapter 7. FINITE ELEMENT ANALYSIS (FEA) STATIC STRUCTURAL ANALYSIS -- Chapter 8. EXPERIMENTAL WORK OF EPUHMWPE MATERIALS -- Chapter 9. THE PERFORMANCE OF EPOXY-UHMWPE AT DIFFERENT INCLINATION AND ANTEVERSION ANGLE. | |
| 520 | _aThis book highlights the critical challenges faced in total hip replacement (THR) procedures, particularly concerning the performance and longevity of acetabular components. Despite advancements in implant technology, issues such as improper orientation and material failure continue to result in complications, including dislocation and wear. Recognizing the need for more reliable solutions, this book explores the optimization of safe zone orientation and the development of composite materials, specifically focusing on metal-on-polymer (MoP) implants. By investigating these factors through numerical analysis, finite element analysis (FEA), and experimental studies, the book seeks to enhance implant performance, reduce failure rates, and ultimately improve patient outcomes in THR surgeries. | ||
| 650 | 0 | _aMedical physics. | |
| 650 | 0 | _aBiomedical engineering. | |
| 650 | 0 |
_aBiomechanics. _966777 |
|
| 650 | 0 | _aBiomaterials. | |
| 650 | 0 |
_aMathematics _xData processing. _965715 |
|
| 650 | 1 | 4 | _aMedical Physics. |
| 650 | 2 | 4 |
_aBiomechanical Analysis and Modeling. _966778 |
| 650 | 2 | 4 | _aBiomaterials. |
| 650 | 2 | 4 |
_aComputational Mathematics and Numerical Analysis. _966073 |
| 650 | 2 | 4 | _aBiomedical Engineering and Bioengineering. |
| 700 | 1 |
_aShuib, Solehuddin. _eauthor. _0(orcid)0000-0003-4012-6188 _1https://orcid.org/0000-0003-4012-6188 _4aut _4http://id.loc.gov/vocabulary/relators/aut _990431 |
|
| 700 | 1 |
_aRomli, Ahmad Zafir. _eauthor. _4aut _4http://id.loc.gov/vocabulary/relators/aut _990432 |
|
| 710 | 2 | _aSpringerLink (Online service) | |
| 773 | 0 | _tSpringer Nature eBook | |
| 776 | 0 | 8 |
_iPrinted edition: _z9789819609741 |
| 776 | 0 | 8 |
_iPrinted edition: _z9789819609765 |
| 830 | 0 |
_aSpringerBriefs in Applied Sciences and Technology, _x2191-5318 _965846 |
|
| 856 | 4 | 0 | _uhttps://doi.org/10.1007/978-981-96-0975-8 |
| 912 | _aZDB-2-PHA | ||
| 912 | _aZDB-2-SXP | ||
| 999 |
_c66507 _d66507 |
||