000 04053nam a22006015i 4500
001 978-981-96-0975-8
003 DE-He213
005 20251030114931.0
007 cr nn 008mamaa
008 250124s2024 si | s |||| 0|eng d
020 _a9789819609758
_9978-981-96-0975-8
024 7 _a10.1007/978-981-96-0975-8
_2doi
050 4 _aR895-920
072 7 _aPHVD
_2bicssc
072 7 _aSCI003000
_2bisacsh
072 7 _aPHVD
_2thema
100 1 _aManap, Muhammad Faris bin Abd.
_eauthor.
_4aut
_4http://id.loc.gov/vocabulary/relators/aut
_990430
245 1 0 _aTotal Hip Replacement (THR)
_h[electronic resource] :
_bEffect of Inclination and Anteversion Angle on the Performance of Epoxy-UHMWPE Acetabular Cup /
_cby Muhammad Faris bin Abd Manap, Solehuddin Shuib, Ahmad Zafir Romli.
250 _a1st ed. 2024.
264 1 _aSingapore :
_bSpringer Nature Singapore :
_bImprint: Springer,
_c2024.
300 _aXVII, 94 p. 52 illus., 39 illus. in color.
_bonline resource.
336 _atext
_btxt
_2rdacontent
337 _acomputer
_bc
_2rdamedia
338 _aonline resource
_bcr
_2rdacarrier
347 _atext file
_bPDF
_2rda
490 1 _aSpringerBriefs in Applied Sciences and Technology,
_x2191-5318
505 0 _aChapter 1. THE EFFECT OF INCLINATION AND ANTEVERSION ANGLE ON THE PERFORMANCE OF EPOXY-UHMWPE ACETABULAR CUP -- Chapter 2. METAL-ON-METAL TOTAL HIP REPLACEMENT AND SAFE ZONE ORIENTATION OF ACETABULAR CUP -- Chapter 3. FINITE ELEMENT ANALYSIS (FEA) OF METAL-ON-POLYMER (MoP) AND ACETABULAR CUP MATERIAL -- Chapter 4. NUMERICAL AND MATHEMATICAL MODELLING FOR ACETABULAR CUP ORIENTATION -- Chapter 5. EXPERIMENTAL WORK OF EPOXY-UHMWPE MATERIALS -- Chapter 6. ANALYTICAL RESULTS OF SAFE ZONE ORIENTATION -- Chapter 7. FINITE ELEMENT ANALYSIS (FEA) STATIC STRUCTURAL ANALYSIS -- Chapter 8. EXPERIMENTAL WORK OF EPUHMWPE MATERIALS -- Chapter 9. THE PERFORMANCE OF EPOXY-UHMWPE AT DIFFERENT INCLINATION AND ANTEVERSION ANGLE.
520 _aThis book highlights the critical challenges faced in total hip replacement (THR) procedures, particularly concerning the performance and longevity of acetabular components. Despite advancements in implant technology, issues such as improper orientation and material failure continue to result in complications, including dislocation and wear. Recognizing the need for more reliable solutions, this book explores the optimization of safe zone orientation and the development of composite materials, specifically focusing on metal-on-polymer (MoP) implants. By investigating these factors through numerical analysis, finite element analysis (FEA), and experimental studies, the book seeks to enhance implant performance, reduce failure rates, and ultimately improve patient outcomes in THR surgeries.
650 0 _aMedical physics.
650 0 _aBiomedical engineering.
650 0 _aBiomechanics.
_966777
650 0 _aBiomaterials.
650 0 _aMathematics
_xData processing.
_965715
650 1 4 _aMedical Physics.
650 2 4 _aBiomechanical Analysis and Modeling.
_966778
650 2 4 _aBiomaterials.
650 2 4 _aComputational Mathematics and Numerical Analysis.
_966073
650 2 4 _aBiomedical Engineering and Bioengineering.
700 1 _aShuib, Solehuddin.
_eauthor.
_0(orcid)0000-0003-4012-6188
_1https://orcid.org/0000-0003-4012-6188
_4aut
_4http://id.loc.gov/vocabulary/relators/aut
_990431
700 1 _aRomli, Ahmad Zafir.
_eauthor.
_4aut
_4http://id.loc.gov/vocabulary/relators/aut
_990432
710 2 _aSpringerLink (Online service)
773 0 _tSpringer Nature eBook
776 0 8 _iPrinted edition:
_z9789819609741
776 0 8 _iPrinted edition:
_z9789819609765
830 0 _aSpringerBriefs in Applied Sciences and Technology,
_x2191-5318
_965846
856 4 0 _uhttps://doi.org/10.1007/978-981-96-0975-8
912 _aZDB-2-PHA
912 _aZDB-2-SXP
999 _c66507
_d66507